For iPhone & iPad

Will a heat pump work for your home? Answer with numbers.

Capture your building room by room, calculate the heat load to DIN EN 12831, simulate the seasonal performance factor and cross-check it against your actual energy use. Built for homeowners and installers.

Room by room
Estimate heat load
~20
guided steps
PDF
report export
Bungalow 1965 project overview with building data, heating system and capture progress.
About WP Planer

Confident planning, not guesswork

Four building blocks that turn a rough estimate into a reliable planning basis.

01

Guided building capture

In about 20 guided steps you record location, year built, building envelope, existing heating and domestic hot water. Then you set up your rooms with windows, doors and radiators – optionally measured by LiDAR.

02

Heat load to standard

Heat load is calculated room by room using the simplified method of DIN EN 12831. Right after, the app checks whether your existing radiators deliver enough output at 55, 45 or 35 °C flow temperature.

03

Annual simulation with climate data

Using climate data for your region, WP Planer simulates a full year: seasonal performance factor, electricity use, cost and bivalence point. Cross-check it against your previous oil or gas consumption.

04

Privacy built in

All building and room data stays on your device – no account, no tracking, no registration. You stay fully in control of your planning.

Features

Everything that matters for confident planning

Eight building blocks in one guided flow – from building capture to PDF report.

Building capture

Location, year built, building envelope, existing heating and domestic hot water – captured in about 20 guided steps.

Rooms, floor plan & 3D

Set up rooms with windows, doors and radiators, arrange them on the floor plan and review the 3D model – optionally measured with LiDAR.

Heat load to DIN EN 12831

Room-by-room calculation using the standard's simplified method – transparent and traceable.

Radiator check

Does the output of your existing radiators suffice at 55, 45 or 35 °C flow temperature? Checked room by room.

Domestic hot water demand

The planner derives your hot water demand from occupant count and chosen comfort level.

Annual simulation

With regional climate data: seasonal performance factor, electricity use, cost and bivalence point at a glance.

Consumption cross-check

Enter your previous oil or gas consumption and check it as a plausibility test against the simulation.

PDF report & JSON export PRO

A full PDF report with room table and simulation, plus a structured JSON export for further processing.

How it works

From building to a number you can trust

Three steps: capture the building, set up the rooms, simulate the year.

Building dimensions of 12 × 9 m and the heated ground floor in the guided flow.
Step 1 · Building

Capture your building in about 20 steps

Location, year built, building envelope, existing heating and hot water – guided step by step, one question per screen. You end up with a complete building profile as the basis for the calculation.

  • Location & regional climate data
  • Year built & insulation standard of the envelope
  • Existing heating & hot water system
Bungalow 1965 floor plan with nine ground-floor rooms and a total area of 108 m².
Step 2 · Rooms

Set up rooms – on the floor plan and in 3D

Set up each room with windows, doors and its existing radiator – entered by hand or measured on the spot with LiDAR. Arrange rooms in the floor plan editor and review the whole building as a 3D model.

  • Windows, doors and radiators per room
  • Floor plan editor & 3D model per storey
  • Optional LiDAR measurement on supported devices
Annual simulation with seasonal performance factor, electricity demand, costs and consumption cross-check.
Step 3 · Calculation

Simulate the year, export the report

Using climate data for your region, WP Planer simulates an entire heating year: seasonal performance factor, electricity use, cost and bivalence point. Compare it with your previous oil or gas consumption and export everything as a PDF report.

  • Seasonal performance factor, cost & bivalence point
  • Plausibility check against previous consumption
  • PDF report with room table & photos (Pro)
Who it's for

Plan on equal footing – from conversation to report

For everyone who wants numbers instead of guesswork before deciding.

Homeowners

Understand what output your home really needs before you get a quote, and whether your existing radiators can stay. Talk to your installer as an equal.

Installers & HVAC firms

Capture buildings on-site in minutes, document rooms with photos and export a full PDF report with room table and simulation.

Energy consultants

Use the standard-based heat load calculation and annual simulation as a solid planning basis for your consulting work.

Pricing

Calculate for free – export as Pro

The full calculation is already included in the free project. Pro unlocks unlimited projects, PDF report and JSON export.

Free

To try it out & calculate

€0 forever
  • 1 project
  • Full building & room capture
  • Heat load calculation to DIN EN 12831
  • Radiator check & annual simulation
  • PDF report
  • JSON export

Subscription renews automatically. Cancel anytime in your iPhone/iPad settings.

Note: This calculation does not replace a code-compliant heat load calculation by a licensed installer, but it provides a solid planning basis. All data stays on your device – no registration, no tracking.

Ready to plan your heat pump with confidence?

Capture your first project for free – the full calculation is included.